HP part number
|
ProCurve Switch 2610-48 (J9088A)
|
ProCurve Switch 2610-24 (J9085A)
|
ProCurve Switch 2610-24-PWR (J9087A)
|
|
Ports
|
48 auto-sensing 10/100 ports (IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-TX)
Media Type: Auto-MDIX
Duplex: half or full
1 RJ-45 serial console port
2 auto-sensing 10/100/1000 ports (IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-TX, IEEE 802.3ab Type 1000Base-T)
Duplex: 10Base-T/100Base-TX: half or full; 1000Base-T: full only
2 open mini-GBIC (SFP) slots
|
24 auto-sensing 10/100 ports (IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-TX)
Media Type: Auto-MDIX
Duplex: half or full
1 RJ-45 serial console port
2 auto-sensing 10/100/1000 ports (IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-TX, IEEE 802.3ab Type 1000Base-T)
Duplex: 10Base-T/100Base-TX: half or full; 1000Base-T: full only
2 open mini-GBIC (SFP) slots
|
24 auto-sensing 10/100 ports (IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-TX)
Media Type: Auto-MDIX
Duplex: half or full
1 RJ-45 serial console port
2 auto-sensing 10/100/1000 ports (IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-TX, IEEE 802.3ab Type 1000Base-T)
Duplex: 10Base-T/100Base-TX: half or full; 1000Base-T: full only
2 open mini-GBIC (SFP) slots
|
|
Physical characteristics
|
|
|
|
| Dimensions |
9.3(d) x 17.4(w) x 1.73(h) in. (23.62 x 44.2 x 4.39 cm) (1U height) |
9.3(d) x 17.4(w) x 1.73(h) in. (23.62 x 44.2 x 4.39 cm) (1U height) |
12.5(d) x 17.4(w) x 1.73(h) in. (31.75 x 44.2 x 4.39 cm) (1U height) |
| Weight |
10.75 lb. (4.88 kg), Fully loaded |
10.2 lb. (4.63 kg), Fully loaded |
15.05 lb. (6.83 kg), Fully loaded |
|
Memory and processor
|
|
|
|
| Processor |
MIPS @ 300 MHz, 16 MB flash, 128 MB SDRAM; packet buffer size: 2 MB |
MIPS @ 300 MHz, 16 MB flash, 128 MB SDRAM; packet buffer size: 1 MB |
MIPS @ 300 MHz, 16 MB flash, 128 MB SDRAM; packet buffer size: 1 MB |
|
Mounting
|
|
|
|
|
|
Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only
|
Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only
|
Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only
|
|
Performance
|
|
|
|
| 100 Mb Latency |
< 6.2 µs (LIFO) |
< 4.1 µs (LIFO) |
< 4.1 µs (LIFO) |
| 1000 Mb Latency |
< 4.4 µs (LIFO) |
< 2.9 µs (LIFO) |
< 2.9 µs (LIFO) |
| Throughput |
up to 13.0 million pps |
up to 9.5 million pps |
up to 9.5 million pps |
| Routing/Switching capacity |
17.6 Gbps |
12.8 Gbps |
12.8 Gbps |
| MAC address table size |
8000 entries |
8000 entries |
8000 entries |
|
Environment
|
|
|
|
| Operating temperature |
32ºF to 122ºF (0ºC to 50ºC) |
32ºF to 122ºF (0ºC to 50ºC) |
32ºF to 122ºF (0ºC to 50ºC) |
| Operating relative humidity |
15% to 95% @ 104ºF (40ºC), non-condensing |
15% to 95% @ 104ºF (40ºC), non-condensing |
15% to 95% @ 104ºF (40ºC), non-condensing |
| Non-operating/Storage temperature |
-40ºF to 158ºF (-40ºC to 70ºC) |
-40ºF to 158ºF (-40ºC to 70ºC) |
-40ºF to 158ºF (-40ºC to 70ºC) |
| Non-operating/Storage relative humidity |
15% to 90% @ 149ºF (65ºC), non-condensing |
15% to 90% @ 149ºF (65ºC), non-condensing |
15% to 90% @ 149ºF (65ºC), non-condensing |
| Altitude |
up to 10000 ft. (3 km) |
up to 10000 ft. (3 km) |
up to 10000 ft. (3 km) |
| Acoustic |
Power: 45 dB, Pressure: 36.2 dB; DIN 45635T.19 per ISO 7779 |
Power: 0 dB, Pressure: 0 dB No Fan |
Power: 62 dB, Pressure: 53 dB; DIN 45635T.19 per ISO 7779 |
|
Electrical characteristics
|
|
|
|
| Maximum heat dissipation |
285 BTU/hr (300.67 kJ/hr) |
142 BTU/hr (149.81 kJ/hr) |
410 BTU/hr (432.55 kJ/hr), ( Switch only BTU/hr - 410, combined switch + maxPoE devices at 15.4 W - 2281 BTU/hr ) |
| Voltage |
100-127 / 200-240 VAC |
100-127 / 200-240 VAC |
100-127 / 200-240 VAC |
| Current |
1.3 / 0.8 A |
0.8 / 0.4 A |
7.0 / 3.5 A |
| Power consumption |
66 W |
41 W |
77 W |
| Frequency |
50 / 60 Hz |
50 / 60 Hz |
50 / 60 Hz |
| Notes |
|
|
Power Consumption - 77 W without PoE; 527 W with PoE |
|
Safety
|
|
|
|
|
|
CSA 22.2 No. 60950
UL 60950
IEC 60950
EN 60950
|
CSA 22.2 No. 60950
UL 60950
IEC 60950
EN 60950
|
CSA 22.2 No. 60950
UL 60950
IEC 60950
EN 60950
|